Goodman · Furnace troubleshooting

High stage pressure switch open, furnace on low stage only

ACVC96AMVC96GCVC96GMVC96

What is going on

Induced draft blower runs but the furnace only operates on low stage.

Likely causes

  • Pressure switch hose blocked, pinched or connected improperly
  • Blocked flue and/or inlet air pipe, blocked drain system, or weak induced draft blower
  • Incorrect pressure switch set point or failing switch contacts
  • Loose or improperly connected wiring

Check in this order

  1. Turn power off before repair.
  2. Replace the pressure switch with the correct part.
  3. Inspect the pressure switch hose and repair or replace if needed.
  4. Inspect flue and/or inlet air piping for blockage, length, elbows and termination. Check the drain system.
  5. Check induced draft blower performance and correct as needed.
  6. Correct the pressure switch set point or contact action.
  7. Tighten or correct the wiring connection.
  8. Replace the induced draft blower with the correct part if it is weak.

Applies to: 34.5 in chassis gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 Service and Troubleshooting, p. 61. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.