Direct vent: standard vertical termination (Option 1)

96V96MDV

What is going on

Standard vertical direct vent termination, Option 1 in the Rheem 96V/96MDV instructions. The big thing is keeping the intake and the vent apart so the furnace doesn't breathe its own exhaust. Keep 12 in of vertical separation, and if you run 3 in pipe, step down to 2 in before the roof.

Likely causes

  • Not a fault call. Termination dimensions for Option 1 vertical direct vent.

Check in this order

  1. Keep 12 in vertical separation between the combustion air intake and the vent.
  2. If using 3 in pipe, reduce both the intake and exhaust pipes to 2 in before the roof penetration.
  3. Follow Figure 23 for the roof penetration detail.
  4. Flash and seal the roof penetration so water stays out.
  5. Support the pipes and check for the proper slope back to the furnace.

Applies to: Direct vent vertical termination

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rheem 96V installation instructions, p. 58. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.