Choosing a condensate disposal method
What is going on
Three disposal options are allowed: direct to an external drain, through a neutralizer then to the drain, or through a condensate pump then to a suitable drain. A pump is used when the drain is far from the furnace or when there is not enough fall for gravity drainage.
Likely causes
- Long run between the furnace and an accessible drain
- Insufficient gradient for gravity drainage
Check in this order
- Pick direct drain, neutralizer, or pump based on the site.
- If a neutralizer is used, the neutralizing agent must be replaced on a schedule that depends on how much the furnace runs.
- If there is not enough fall, install a drain pump rated for boiler, water heater and furnace condensate.
- Keep the condensate line from freezing or being blocked, or condensate can leak from the drain.
Applies to: NPF700 series
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.