Navien · Furnace troubleshooting
Gas regulator arrangements for LP supply
What is going on
The manual shows a single regulator system (12 in WC) and a two stage system with a high pressure and a low pressure regulator. The two stage system is recommended.
Likely causes
- Supply pressure or tank arrangement does not suit a single regulator
Check in this order
- Use the single regulator (12 in WC) layout only where it suits the site.
- Prefer the two stage layout a high pressure regulator at the tank feeding a low pressure regulator that goes to the building.
- Keep full size gas pipe run to the appliance.
- Check the excess flow valve rating before installing one (see the EFV tip).
Applies to: NPF700 series on LP gas
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 47. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.