Venting configuration (direct vent or non-direct vent)
What is going on
The furnace can go in as a Direct Vent or a Non-Direct Vent unit, and the choice changes where the combustion air comes from. With Direct Vent the air is drawn from outdoors through its own pipe. With Non-Direct Vent the furnace takes air from the room, so the space has to have enough of it. Either way, the flue gases leave the house through the exhaust pipe. Figure 2 in the manual shows roof termination layouts, so decide before you start cutting pipe.
Likely causes
- Tight house or finished basement with limited indoor air, which favors Direct Vent
- Corrosive vapours, dust or chemicals indoors that make indoor air a poor choice
- Existing vent layout that decides which option fits
- Code requirements for combustion air in the mechanical room
Check in this order
- Choose Direct Vent or Non-Direct Vent before installing, because the piping differs.
- For Direct Vent, bring combustion air from outdoors through the intake pipe.
- For Non-Direct Vent, supply combustion air from indoors per the National Fuel Gas Code or CSA-B149.
- Use Figure 2 for roof termination layouts.
- After install, run a full heating cycle and look for flue gas leaks at every joint.
- Make sure intake and exhaust terminations are clear of snow, leaves and obstructions.
Applies to: A95UH, A93UH, 95G1UH and 92G1UH
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Allied 92G1UH installation manual, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.