Navien · Furnace troubleshooting

Relocating the junction box to the opposite side panel

NPF

What is going on

The furnace ships with the junction box set for right side line voltage entry. Move it to the other side before making line connections there.

Check in this order

  1. Remove the bottom compartment door.
  2. Remove and save the two screws that secure the junction box to the side panel.
  3. Move the junction box with its plugs and grommets to the opposite side panel.
  4. Secure it with the saved screws.
  5. Keep the wire routing clear of filter removal and routine maintenance.

Applies to: NPF furnace line voltage entry

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 78-79. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.