High fuel consumption

What is going on

If your oil bill keeps climbing and the weather has not changed, the burner is probably wasting fuel. Usually the nozzle is worn, the chamber is dirty or there is too much air going up the stack. Cleaning and tuning the burner with proper test instruments normally brings consumption back down.

Likely causes

  • Worn or loose nozzle, or poor air and oil mixing
  • Dirty chamber or heat exchanger
  • Too much combustion air, or air leaking into the chamber
  • Low overfire draft
  • Wrong oil pressure or overfiring, shown by a high stack temperature

Check in this order

  1. Replace the nozzle with the correct size and angle for the unit
  2. Clean the chamber and heat exchanger
  3. Check the pump pressure against the nameplate
  4. Take a stack temperature and draft reading
  5. Seal any air leaks around the chamber, observation door and burner mount
  6. Tune the air with a combustion test and compare against the target numbers in the manual

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.