Navien · Furnace troubleshooting
Install the condensate neutralizer kit
What is going on
Use the Navien neutralizer kit when condensate goes to a drain through neutralizing media, which raises the pH and protects the drain system and public sewer.
Likely causes
- Local codes or the site require neutralized condensate
Check in this order
- Do not let exhaust flue gases pass through the neutralizer, as this can cause carbon monoxide poisoning.
- Mount the neutralizer on a wall or floor with the brackets supplied.
- Keep the neutralizer inlet and discharge closer to the floor than the condensate drain.
- Install an overflow bypass between the appliance and the neutralizer to stop backflow into the appliance.
- If the neutralizer is horizontal, rotate it so the outlet is the highest point.
- If it is vertical, make sure the outlet is higher than the inlet.
- Use corrosion resistant piping and secure it so it does not move.
- If more than one appliance feeds the neutralizer, size it correctly for the total load.
Applies to: NPF700 series with neutralizer disposal
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 41. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.