Supply air temperature sensor fault (open or short)
What is going on
When the supply air sensor reads open or short, the furnace drops to Emergency heat mode and keeps heating.
Likely causes
- Supply air temperature sensor is open.
- Supply air temperature sensor is shorted.
Check in this order
- Confirm the furnace is in Emergency heat mode.
- Replace the supply air temperature sensor.
- Verify the furnace returns to Normal operation and runs a heating cycle.
- In Emergency heat mode, the coil water target is 140°F (60°C) and airflow stays on normal control.
Applies to: Supply air control mode
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 97. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.