Navien · Furnace troubleshooting

Installation checklist: DIP switches and owner handover

NPF

What is going on

Final checks on switch settings and customer handover.

Check in this order

  1. Confirm DIP switch 1 is set for LP (ON) or NG (OFF) to match the gas supply.
  2. Confirm DIP switch 2 is set for long vent (ON) or short vent (OFF) to match the installed vent.
  3. Give the Installation and Operation Manual and User's Information Manual to the owner.
  4. Show the owner how to shut off the gas in an emergency.

Applies to: NPF700 series (all listed models)

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 94. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.