All brands · Furnace troubleshooting

Limit opens

What is going on

If your furnace shuts the burner off partway through a cycle, the high limit is usually doing its job. It opens when the heat exchanger gets hotter than it should be, which is almost always an airflow problem. Check the filter first, it's cheap and it's the usual culprit.

Likely causes

  • Blower not running
  • Low airflow from a dirty filter, restricted ducts or a dirty blower
  • Overfiring

Check in this order

  1. Switch the thermostat to fan on and confirm the blower runs
  2. Check and replace the furnace filter
  3. Look at the supply and return registers and ducts for blockage
  4. Clean the blower wheel if it's loaded with dust
  5. Check gas input against the rating plate, which is a licensed tech job
  6. Never bypass or jumper the limit

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.