Rheem · Furnace troubleshooting
Non-direct vent: RXGY-G02 sidewall vent kit
What is going on
On the Rheem 96V/96MDV, the RXGY-G02 sidewall vent kit works for non-direct vent as well as direct vent installs. The full instructions live in the direct vent section under Option 8. Follow the manual closely, because vent work affects combustion safety and a mistake can allow flue gases into the home.
Likely causes
- Not a fault call. Venting option for non-direct vent sidewall termination (Option 4).
Check in this order
- Confirm the install really is non-direct vent and the sidewall termination is the route you want.
- Use the RXGY-G02 kit for non-direct venting if preferred.
- Follow the Option 8 direct-vent sidewall instructions for installation details.
- Check clearances and local code requirements before cutting the wall.
- After the install, run the furnace and verify the vent is sealed and tight.
- Test for carbon monoxide at the vent and in the house before leaving.
Applies to: Non-direct vent sidewall termination (Option 4)
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rheem 96V installation instructions, p. 56. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.