Display blank, furnace dead - Goodman *MVC95/*CVC9
What is going on
The two-digit display shows nothing and the furnace does nothing. A ComfortNet thermostat may show INTERNAL FAULT EE with Call for Service.
Likely causes
- Disconnect switch off, blower door switch open, or 24 V wire loose
- Blown fuse or tripped breaker
- Internal fault in the furnace control
Check in this order
- Safety turn power off before touching the control. Discharge static to a bare metal part of the cabinet first.
- Confirm 115 V at the furnace and that the blower door is closed on its switch.
- Check for 24 V at the control.
- Check the 3 A fuse on the control. Replace with a 3 A automotive fuse only, after you find any short in the 115 V or 24 V wiring.
- If power and fuse are good and the display is still blank, replace the control with the correct part.
Applies to: GMVC95/AMVC95 upflow and *CVC9 counterflow two-stage furnaces
More furnace guides
- Airflow lower than demanded, furnace runs on low stage when high stage is expected
- Alternate combustion air opening (upflow or horizontal)
- Alternate vent/flue location (upflow or horizontal left)
- Annual inspection checklist
- Auxiliary limit control (location and purpose)
- Auxiliary limit switch open (blower compartment)
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Goodman *CVC9/95 & *MVC95 Installation Instructions IO-341D (08/2010), Troubleshooting Chart p.53; Electrostatic Discharge p.49. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.