Wire a dehumidistat to the sub controller

NPF

What is going on

Dehumidistat must run on 24 VAC and use a switch that opens when humidity rises. During a combined cooling and dehumidification call the blower runs at about 85% of the desired speed.

Check in this order

  1. Turn off power to the furnace.
  2. Connect the dehumidistat neutral wire (usually white) to the DEH terminal on the sub controller.
  3. Connect the dehumidistat hot wire (usually black) to the R terminal on the sub controller.
  4. Connect the dehumidistat ground wire (usually green) to the ground screw on the junction box, if present.
  5. Restore power and turn on the dehumidification function on the front control panel.

Applies to: NPF700 Hydro-furnace with optional dehumidistat

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 83. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.