Goodman · Furnace troubleshooting
Delayed ignition check
What is going on
Delayed ignition is when the gas-air mixture sits in the chamber a moment too long before it lights. When it finally catches, it can go off with a bang or roll out and burn in the burner venturi. A properly built furnace is not likely to do this unless someone has bypassed controls, so if you hear a thump at startup, look for what has changed or gone out of shape. It is something you want fixed right away, since a rolling flame can damage parts and is a hazard.
Likely causes
- Improper gas pressure
- Burners not seated in locating slots or not level
- Carry-over (lighter tube or cross lighter) obstructed
- Main burner orifice deformed or out of alignment
Check in this order
- Check and adjust gas pressure to rating plate values. Gas work belongs to a licensed gas technician
- Confirm burners sit in the locating slots and are level front to rear and left to right
- Clean the carry-over (lighter tube or cross lighter) so flame can travel burner to burner
- Replace any deformed or misaligned main burner orifice
- Watch a full ignition after repairs and look for flame lighting quickly and evenly across all burners
- If anything was bypassed in the controls, restore it to factory configuration
Applies to: Main burners and ignition
More furnace guides
- Airflow lower than demanded, furnace runs on low stage when high stage is expected
- Alternate combustion air opening (upflow or horizontal)
- Alternate vent/flue location (upflow or horizontal left)
- Annual inspection checklist
- Auxiliary limit control (location and purpose)
- Auxiliary limit switch open (blower compartment)
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Goodman GMVC96 service manual, p. 54. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.