Goodman · Furnace troubleshooting

Delayed ignition check

A/GMVC96A/GCVC96

What is going on

Delayed ignition is when the gas-air mixture sits in the chamber a moment too long before it lights. When it finally catches, it can go off with a bang or roll out and burn in the burner venturi. A properly built furnace is not likely to do this unless someone has bypassed controls, so if you hear a thump at startup, look for what has changed or gone out of shape. It is something you want fixed right away, since a rolling flame can damage parts and is a hazard.

Likely causes

  • Improper gas pressure
  • Burners not seated in locating slots or not level
  • Carry-over (lighter tube or cross lighter) obstructed
  • Main burner orifice deformed or out of alignment

Check in this order

  1. Check and adjust gas pressure to rating plate values. Gas work belongs to a licensed gas technician
  2. Confirm burners sit in the locating slots and are level front to rear and left to right
  3. Clean the carry-over (lighter tube or cross lighter) so flame can travel burner to burner
  4. Replace any deformed or misaligned main burner orifice
  5. Watch a full ignition after repairs and look for flame lighting quickly and evenly across all burners
  6. If anything was bypassed in the controls, restore it to factory configuration

Applies to: Main burners and ignition

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 service manual, p. 54. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.