Pressure switch open / stuck

What is going on

Pressure switch open or stuck. Usually the board will tell you which, by the flash code.

Likely causes

  • Inducer off or weak because the motor or wheel is failing
  • Blocked vent or intake
  • Condensate in the switch hose or trap
  • Code confusion: 2 flashes means stuck closed and 3 means stuck open

Check in this order

  1. Cut power and check the vent and combustion air intake for blockage
  2. Inspect the hose for water or cracks and drain the trap
  3. Check the inducer runs and the wheel is clean
  4. Find the flash code and compare with the chart, 2 is stuck closed and 3 is stuck open
  5. Meter the switch with a manometer to confirm it closes at its rated pressure
  6. Replace the switch only after confirming it, never jumper it

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.