Flame burns a few seconds then out

What is going on

If your oil burner lights, burns a few seconds and then drops out, the control is telling you it lost the flame or never really proved it. That can be a flame sensor problem, but it is often a fuel or air problem that makes the flame unstable. Here is how I would sort it out.

Likely causes

  • Cad cell or stack switch mispositioned, dirty or faulty
  • Too much air, cold air, or a lean flame that will not hold
  • Fuel supply trouble: empty or unvented tank, clogged filter, ice, water or dirt in the line, or a loose fitting pulling air
  • Fuel unit problems: bad pump, losing prime, slipping coupling or pressure swinging, or the wrong bypass plug
  • Clogged or damaged nozzle

Check in this order

  1. Check tank level and vent, then look at the filter for water or sludge
  2. Make sure the cad cell or stack switch is seated, can see the flame, and is clean
  3. Watch the pump gauge during the run; a falling or swinging needle points to air or a weak pump
  4. Tighten every line fitting and check the coupling is not slipping
  5. Inspect the nozzle and confirm the bypass plug matches a one-pipe or two-pipe system
  6. Adjust the air for a stable flame, ideally with a combustion test

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.