Leak testing new gas piping
What is going on
Leak test all new gas piping and any section not yet pressure tested, such as from the manual shut-off valve to the furnace gas valve. Pressure test per CAN/CSA-B149.1 and 2, NFPA 54, ANSI Z223.1, or ANSI/NFPA 58.
Check in this order
- Pressure test new gas piping as the applicable code specifies.
- Test untested sections with an electronic combustible gas detector, a commercial leak detector, or another locally approved method.
- Never use a match, lighter, flame, or other ignition source to find leaks.
- At the furnace, use leak detection solution on the gas valve/manifold connection and burner orifices, and on pressure boss screws. Bubbles mean a leak.
- Shut off gas and repair all leaks before continuing.
Applies to: New gas piping and gas valve connections
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF installation and operation manual, p. 48, 50, 52. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.