Navien · Furnace troubleshooting

Slow or debris-filled condensate drain

NDF

What is going on

Water should flow easily through the condensate drain line. Blocked drainage can back condensate into the heat exchanger and cause nuisance pressure switch or roll-out switch trip-outs.

Likely causes

  • Blocked drain trap assembly or other drain component
  • Debris, dirt or carbon in the condensate

Check in this order

  1. Observe the drain line for water flow and for signs of dirt, carbon or debris.
  2. Clean the drainage system if needed, including the drain trap assembly.
  3. If the drain lines are opaque, have the service technician check them during annual service.
  4. Refer excess debris in the drain line to the service contractor.

Applies to: NDF forced air gas furnace

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NDF installation and operation manual, p. 90-91. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.