Goodman · Furnace troubleshooting

Multiple direct vent furnaces at one termination

34.5 in Chassis ACVC96/AMVC96/GCVC96/GMVC96

What is going on

Multiple direct vent Goodman furnaces on one roof or one side wall. Same clearances as a single unit, per pair. Keep terminals level.

Likely causes

  • Adjacent terminations closer than the single-unit clearances
  • Exhaust outlets at different elevations
  • Air intakes at different elevations, so one furnace pulls in another's flue gas

Check in this order

  1. On a common roof, keep the same minimum clearances between exhaust and intake terminations of adjacent units as for a single unit.
  2. On a common side wall, follow the clearance figure in the manual.
  3. Terminate all exhaust outlets at the same elevation.
  4. Terminate all air intakes at the same elevation.
  5. Check the layout against the manual before drilling any holes.

Applies to: Multiple direct vent furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 service manual, p. 19. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.