Goodman · Furnace troubleshooting

Grounding fault

ACVC96AMVC96GCVC96GMVC96

What is going on

The furnace doesn't run and the board is showing a grounding error. The control needs a solid ground and a good neutral before it will light anything, and a loose or poor neutral is the usual cause.

Likely causes

  • Poor neutral connection
  • Loose or corroded ground at the furnace or at the panel

Check in this order

  1. Turn power off before service.
  2. Verify the neutral wire connection to the furnace and its continuity to the ground source.
  3. Tighten and clean the neutral and ground terminals at the furnace and at the panel.
  4. Restore power and check for about 120 V between hot and neutral, with very little voltage between neutral and ground.
  5. Don't use the gas line as a ground.

Applies to: 34.5 in chassis gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Goodman GMVC96 Service and Troubleshooting, p. 62. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.