Condensate drain not freezing or draining properly in attic or unconditioned space

NPF

What is going on

Frozen condensate lines block the drain and shut the furnace down.

Likely causes

  • Drain line routed through unconditioned or uncontrolled space
  • Drain line below freezing temperature

Check in this order

  1. Do not install condensate drain lines in unconditioned or uncontrolled spaces where temperatures can drop below freezing.
  2. If the line must pass through a cold space, apply UL listed heat tape rated 5 to 6 W/ft at 120 V.
  3. Use self-regulating or thermostatically controlled heat tape.
  4. Route the trap to a field-supplied condensate disposal system.

Applies to: NPF furnace condensate drain

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 73-75. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.