Allied · Furnace troubleshooting
Unit fails to operate
What is going on
Check these items in order before calling for service.
Likely causes
- No heat call from thermostat
- Access panel not secured
- Main disconnect open
- Blown fuse or tripped breaker
- Dirty or plugged filter, which causes the limit control to shut the unit off
- Gas off at the meter
- Manual main shut-off valve closed
- Internal manual shut-off valve closed
- Ignition system in lockout
Check in this order
- Confirm the thermostat is calling for heat.
- Confirm all access panels are secure.
- Confirm the main disconnect is closed.
- Check for a blown fuse or tripped breaker.
- Check and replace or clean the filter if dirty or plugged.
- Confirm gas is on at the meter.
- Open the manual main shut-off valve.
- Open the internal manual shut-off valve.
- If the ignition system is in lockout, reset by moving the thermostat off and back to heat. If it locks out again, inspect the unit for blockages.
Applies to: No burner operation
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Allied 92G1UH installation manual, p. 46. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.