Puff-back / delayed ignition

What is going on

A puff-back or delayed ignition is a small oil explosion in the chamber because the oil sprayed for a moment before the flame lit. It can blow soot out of the barometric damper and in bad cases damage the heat exchanger or flue. Shut the unit off at the service switch and have it looked at before running it again, and leave the final adjustment to a licensed oil technician.

Likely causes

  • Water in the oil, or air in the fuel line
  • Electrodes mispositioned or loose, or insulators carbonized
  • Bad nozzle or spray pattern distorted away from the electrodes
  • Voltage drop at start, loose or dirty transformer leads, or a weak transformer
  • Wrong oil pressure, excessive air or high draft

Check in this order

  1. Turn off power, then check the tank bottom and filter for water and sludge
  2. Check electrode gap and position and clean carbon off the insulators
  3. Replace the nozzle and confirm the spray pattern is centred on the electrodes
  4. Tighten transformer leads and check the contacts for dirt
  5. Meter the line voltage while the burner starts to catch any voltage drop
  6. Gauge the pump pressure and bleed the line to clear air
  7. Check draft and air setting, then confirm a quick, clean light-off

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.