Navien · Furnace troubleshooting

Selecting a vent type (direct vent preferred)

NPF

What is going on

The furnace is a Category IV appliance set at the factory for direct vent (sealed combustion). Direct vent is preferred so combustion air stays clean and the building envelope is not affected. If direct vent is not possible, make sure there is enough make-up air in the room. A new vent system is recommended; a reused system must be checked for fit, punctures, cracks and blockages.

Check in this order

  1. Use direct vent whenever possible.
  2. If reusing an existing vent, inspect it for punctures, cracks and blockages before connecting.
  3. For direct vent, make an airtight seal from the furnace collar to the termination.
  4. Intake pipe may be ABS, PVC, CPVC, PP, galvanized or stainless steel.
  5. Pipe size is 2 in or 3 in for both exhaust and intake.
  6. If direct vent is not used, confirm ample make-up air at the installation location.

Applies to: Furnace vent type selection

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 64. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.