Navien · Furnace troubleshooting

Furnace runs longer than the thermostat set point (heating)

NPF

What is going on

Heating runs long when the furnace RA set temperature is below the thermostat set point.

Likely causes

  • RA set temperature is lower than the thermostat set point.
  • Heat output is not enough to reach the thermostat set point in time.

Check in this order

  1. Compare the thermostat set point with the furnace RA set temperature.
  2. Set the RA set temperature at or above the thermostat set point.
  3. If heating still runs over four hours, confirm the Boost function activates to satisfy the thermostat.
  4. Or enable Indoor Estimate Temp mode so the furnace estimates the set point automatically.

Applies to: Return air control mode

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 96. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.