Navien · Furnace troubleshooting

Cut side return opening and connect supply duct

NPF

What is going on

Guide dimples mark the side return opening. Do not cut larger than marked. An undersized opening reduces airflow.

Likely causes

  • Cutting larger than the marked opening can cut into the water compartment.
  • Connecting supply air to the furnace side or to anything other than the supply flanges.

Check in this order

  1. On upflow units, use a straight edge to scribe lines between the guide dimples.
  2. Cut the side return opening on these lines only.
  3. Connect the supply duct only to the furnace supply flanges or the evaporator coil casing.
  4. Do not cut the side of the main casing to attach ducts, humidifiers or accessories.
  5. For furnaces without an evaporator coil, fit a removable access panel to the outlet duct.

Applies to: NPF700 hydro-furnace duct connections

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 56. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.