Low stage pressure switch open, induced draft blower runs continuously
What is going on
Induced draft blower keeps running and the furnace does not continue to operate.
Likely causes
- Pressure switch hose blocked, pinched or connected improperly
- Blocked flue and/or inlet air pipe, blocked drain system, or weak induced draft blower
- Incorrect pressure switch set point or failing switch contacts
- Loose or improperly connected wiring
Check in this order
- Inspect the pressure switch hose and repair or replace it if needed.
- Inspect flue and/or inlet air piping for blockage, correct length, elbows and termination. Check the drain system.
- Check induced draft blower performance and correct as needed.
- Correct the pressure switch set point or contact action.
- Tighten or correct the wiring connection.
- Turn power off before repair.
- Replace the pressure switch or the induced draft blower with the correct part if they fail.
Applies to: 34.5 in chassis gas furnaces
More furnace guides
- Airflow lower than demanded, furnace runs on low stage when high stage is expected
- Alternate combustion air opening (upflow or horizontal)
- Alternate vent/flue location (upflow or horizontal left)
- Annual inspection checklist
- Auxiliary limit control (location and purpose)
- Auxiliary limit switch open (blower compartment)
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Goodman GMVC96 Service and Troubleshooting, p. 60. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.