Navien · Furnace troubleshooting

Condensate drain setup and trap mounting

NDF

What is going on

The furnace can make up to about 4-1/2 lb of water per hour (about 2 imperial quarts, 2-1/2 US quarts or 2-1/4 liters). Provide a drain path, and protect drains and traps from freezing in spaces that can drop below freezing.

Check in this order

  1. Mount the condensate trap on the outside of the blower compartment side panel for upflow. For horizontal positions, mount it on the exterior side panels.
  2. Use the drain hose supplied. Cut it to length for the application so it does not kink, and make sure it can reach the side panel.
  3. Secure the large plastic clamps on the front manifold cover drain outlet and on the 5/8 in barbed fitting of the trap.
  4. Secure the small plastic clamp on the inducer drain collar and on the 1/2 in barbed fitting of the trap.
  5. Tighten the clamps firmly with pliers.
  6. Angle the inducer drain holes about 15 degrees downward.
  7. Slope the drain tubing toward the trap and make sure no hose sections form a trap before the condensate trap.
  8. Push barbed fittings fully into the trap and hoses until they seat on the barb flange.
  9. Prime the condensate trap with water before the first startup.
  10. Protect drains and traps from freezing where the space can reach freezing temperatures.

Applies to: Upflow and horizontal installations

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NDF installation and operation manual, p. 37-38. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.