Trane · Furnace troubleshooting
Install alternate upflow filter clip / bracket kit (KIT09224)
What is going on
KIT09224, alternate upflow filter clips. Side return uses the cabinet dimples, bottom return has holes drilled already. Leaf spring clip goes at the rear.
Likely causes
- Clips mounted at the wrong location for the return type
- Leaf spring clip installed at the front instead of the rear
- Screws started without pre-drilled clearance holes at the dimples
Check in this order
- Pick the location. Dimples mark where the alternate clips go on side return cabinets. Bottom return holes are already drilled.
- Pre-drill clearance holes with a 3/16 in drill at side return dimples.
- Install the clips at the front and rear of the location with the screws supplied.
- Mount the clip with the leaf spring at the rear of the cabinet.
- Slide the filter in and check it sits flat and holds.
Applies to: Upflow furnace side or bottom return with alternate clips
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane AUH1B080A9421B installer's manual, p. 17. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.