Navien · Furnace troubleshooting

Non-direct vent (single pipe) back-draft risk

NPF

What is going on

If the installation location can go into negative pressure, cold air can be drawn back through the heat exchanger, which can freeze it and cause a malfunction. Freezing from back-draft is not covered by the warranty. If there is any doubt about back-draft, use direct venting.

Likely causes

  • Negative pressure at the installation location
  • Poorly balanced air supply in the home

Check in this order

  1. Check whether the installation location could go into negative pressure.
  2. If there is any question, use a direct vent system instead.
  3. Confirm the non-direct vent clearances on the termination clearance table (p. 68).
  4. Provide two combustion air openings sized per the make-up air table (p. 67).

Applies to: Non-direct vent installations

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 66-67. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.