Reduced pressure, smoky shutdowns, lockouts

What is going on

Pressure drops, smoky shutdowns, random lockouts. Classic air in the fuel. Bleed it first. If it keeps coming back, find the leak or add a deaerator.

Likely causes

  • Air in the fuel line from a leak or a low tank
  • Loose fitting or cracked filter housing on the suction side
  • No deaerator on a system that keeps building air

Check in this order

  1. Bleed the pump at the bleed port until the oil runs solid with no foam
  2. Tighten fittings and check the filter gasket on the suction side
  3. Watch the pressure gauge for flutter after bleeding
  4. If the problem returns, install a deaerator
  5. On a one-pipe system, make sure the bypass plug is removed or left per the manual
  6. Retest start and stop cycles for clean cutoff

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.