Draining the water tank and condensate trap (upflow and downflow models)
What is going on
Use this to empty the water side when the furnace will sit unused for a long time. Damage from freezing is not covered by the warranty.
Check in this order
- Turn each knob on the upper front cover counterclockwise, remove the cover, then pull the lower front cover back and out.
- Connect the 3/4 in condensate hose from the installation kit to the drain adapter.
- Turn the drain valve on the drain adapter 90 degrees clockwise, then lift the lever on the pressure relief valve to open it.
- Drain the water tank for more than 5 minutes, then close the drain valve and the pressure relief valve.
- Remove the four screws from the bracket holding the front control panel and sub controller, then take them out of the furnace.
- Connect a 1/4 in pipe to the circulation pump drain adapter. On downflow models, also connect a pipe to the water coil drain adapter. Turn the drain cock on the adapter counterclockwise to open it.
- After the circulation pump is fully drained, close the drain cock. On downflow models only, the water coil drain valve is also present.
- Remove the end cap and stopper from the condensate trap and drain the water, then reinstall the cap and stopper.
Applies to: NPF700 upflow and downflow models
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 142-143. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.