Navien · Furnace troubleshooting

Combustion air inlet protection for non-direct vent

NDF

What is going on

Protect the combustion air inlet from blockage when using indoor combustion air.

Check in this order

  1. If supplying combustion air through the top of the furnace, use a double elbow arrangement.
  2. If supplying combustion air through the side, use a single elbow pointing downward.
  3. Install and secure an 8 in (20 cm) piece of intake pipe with a 90 degree elbow to keep objects out of the burner area.
  4. If outside wall grills are used, size them for 50 percent free area, since most sidewall grills have only 50 percent free area.
  5. Example a 100,000 Btu/hr unit needing a pair of 8 in round pipes may use an 8 in x 7 in equivalent duct, which requires 14 in x 8 in grills at 50 percent free area.

Applies to: NDF600 series furnaces, non-direct vent installations

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NDF installation and operation manual, p. 24, 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.