Remove the upper front cover and attach the intake and exhaust collars with the VID sensor cable routed through the cabinet. The exhaust collar connector must be connected to the VID sensor connector or the furnace will not run.

Check in this order

  1. Remove the plastic caps from the intake and exhaust connections.
  2. Turn the three knobs on the upper front cover counterclockwise and remove the cover.
  3. Route the VID sensor cable through the hole, attach the intake and exhaust collars to the duct holes and tighten the screws.
  4. Insert the intake filter at the bottom of the intake air collar.
  5. Connect the exhaust collar connector to the VID sensor connector inside the furnace.
  6. Reinstall the upper front cover, seat it fully and tighten the three knobs clockwise.
  7. Install the condensate trap on the left or right side of the furnace (see section 2.14).

Applies to: NPF700 all models

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF installation and operation manual, p. 31. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.