Install intake coupling, air diffuser, intake pipe and flue pipe (steps 6-7)
What is going on
Install the intake and flue hardware on the blower shelf and secure the pipe collars. The air diffuser can fall out of the coupling, so the manual allows installing it after the furnace is turned horizontal.
Check in this order
- Install the intake coupling in the blower shelf hole. Insert the air diffuser until the tabs are seated.
- Slide the intake pipe through the left side knockout. Clean it and PVC glue it to the intake coupling.
- Insert the flue pipe assembly through the right side knockout, from under the plate. Slide the angled end through the blower shelf opening and align it with the elbow coupling.
- Secure the flue pipe assembly to the blower shelf with 2 screws. Make sure the O-ring is fully seated.
- Slide the pipe collar assemblies over the 2 pipes. Drill 8 holes of 1/8 in using the collars as a template.
- Secure the collars with 8 screws.
Applies to: Horizontal conversions
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Rheem 96V installation manual, p. 36. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.