Navien · Furnace troubleshooting
Gas supply connection and leak check
What is going on
Gas connections must be made by a licensed professional. Size the line and check for leaks before the furnace is put into service.
Likely causes
- Gas meter capacity is smaller than total connected appliance load
- Gas line not pressure tested or purged before connection
Check in this order
- Confirm gas type and pressure on the rating plate.
- Connect the furnace as the first appliance downstream of the gas meter. Gas meter capacity must be at least the total load of all connected appliances.
- Pressure test the main gas supply line.
- Purge the gas line of debris.
- Size the gas line using the pipe sizing tables.
- Install certified full port valves on the supply line.
- Follow the regulator manufacturer or local code for distance from regulator to appliance.
- Install a manual gas shut-off valve between the supply and the furnace, and a drop leg.
- Use a 1/2 in gas connection. Use 1/2 in rigid pipe only within the sizing table limits. Do not use 1/2 in corrugated connectors.
- Install a union close to the furnace on rigid pipe for future service.
- Hold the furnace connector with one wrench and tighten the pipe with the other to avoid damage.
- Support the piping with hangers. Do not let the furnace or its accessories carry the pipe weight.
- Do not run a flexible gas connector inside the cabinet. Use a new listed connector only where local codes allow it, and not one that served another gas appliance.
- Massachusetts requires flexible connectors under 36 in.
- Keep flexible lines free of crimps and tight bends and sized for the required BTU load.
- Check all joints with a bubble test. Never use a flame.
- Turn off the furnace and gas supply if a leak is found, repair it, and do not restart until the leak is fixed.
Applies to: NPF700 series
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NPF installation and operation manual, p. 44-46. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.