Rheem · Furnace troubleshooting

No heat - POWER LED off

What is going on

When a Rheem 90 Plus condensing furnace (the (-)GRC/(-)GTC and 90RJ/90TJ) is dead on a heat call and the POWER LED on the integrated furnace control is dark, what I usually find is simply no power getting in, most often a tripped breaker or a door switch not made. Less often it is a bad transformer or a blown fuse on the board. Start at the panel and work toward the board.

Likely causes

  • Breaker off or tripped
  • Blower door switch open because the door is off or not seated
  • No line power to the furnace
  • Failed transformer or blown IFC fuse

Check in this order

  1. Warning: hazardous line voltage. Disconnect power before servicing; the work must be done by a trained, qualified service technician.
  2. Check the breaker and line power to the furnace, and the service switch if one is fitted
  3. Check the blower door switch is closed with the door installed properly; never defeat it
  4. Check the transformer and measure for 24 V at the IFC
  5. Check the IFC fuse, and if it blew, look for a shorted thermostat wire or accessory before replacing it

Applies to: Rheem (-)GRC/(-)GTC and 90RJ/90TJ 90 Plus condensing gas furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rheem (-)GRC/(-)GTC Installation Instructions 92-24161-88-00, Figure 56 IFC Troubleshooting Guide, p.54 (printed); Rheem 90RJ/90TJ Installation Instructions 92-24161-32-08, Figure 53, p.54. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.