Navien · Furnace troubleshooting
Converting natural gas to LP
What is going on
The furnace is built for natural gas and can be converted to LP with the factory conversion kit. The kit includes instructions, orifices for all models, the gas valve regulator spring, and a label. Keep removed parts with the furnace for any future conversion back to natural gas.
Check in this order
- Use the Conversion NG to LP Kit instructions for the full procedure.
- Install the included low pressure cut-off switch, which is required for LP operation.
- Install the conversion label next to the rating plate.
- Keep all removed parts with the furnace.
- Check inlet pressure and manifold pressure after conversion.
Applies to: Natural gas to LP conversion
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Navien NDF installation and operation manual, p. 50. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.