Navien · Furnace troubleshooting

Routine maintenance checklist

NPF

What is going on

Minimum maintenance for the NPF hydro-furnace, done by a qualified service provider where noted.

Check in this order

  1. Inspect the air filter monthly and clean or replace it as needed.
  2. Run the pre-inspection through the service wizard on the front control panel.
  3. At the start of each heating and cooling season, check the blower motor and wheel, and clean or service them as required.
  4. Confirm all electrical wiring is connected properly and that the controls work.
  5. Each heating season, check the combustion chamber for leaks and make sure the combustion intake filter is not blocked.
  6. Check the water level on the front control panel before each heating season, and fill the tank to its maximum level if water is added manually.
  7. Inspect the vent pipe and vent system for leaks or damaged pipes and fittings. Repairs must be done by a qualified service provider.
  8. Service any attached accessories (humidifier, electronic air purifier, etc.) per their instructions.
  9. Clean the fins and tubes regularly and check for corrosion, leaks and proper airflow around the unit.

Applies to: NPF700 series furnaces

More furnace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NPF Condensing Hydro-furnace installation and operation manual, p. 130. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.