All brands · Furnace troubleshooting
Locks out — oil but no ignition
What is going on
The burner runs and oil is being delivered, but the flame never lights, so the primary control shuts the unit down on safety. Shut off the service switch before you open anything up, because the ignition transformer puts out high voltage that can hurt you. Work from the ignition side first: electrodes, wires, transformer, then the supply voltage feeding them.
Likely causes
- Electrodes mispositioned or carbonized, or the gap too wide or too close
- Cracked insulators, or worn, loose or dirty ignition wires
- Dead ignition transformer or igniter, or bad primary wires
- Low line voltage or loose wiring at the control
Check in this order
- Turn off power and confirm it is off before removing the burner assembly or touching the electrodes
- Check electrode gap and position against the burner manual and clean off carbon buildup
- Look over the insulators for hairline cracks and replace any that are cracked
- Inspect ignition wires and connections for looseness, wear and dirt
- With power restored, meter the line voltage at the primary control and confirm there is a spark; leave transformer output testing to a licensed oil technician
- Replace the transformer or igniter if wiring and electrodes check out and there is still no spark
More furnace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.