Mini-split troubleshooting guides
396 guides. Not cooling or heating, leaks and communication faults on ductless systems. Each one lists the likely causes and what to check, in order.
All brands (3)
- Indoor unit leaking water
Water is dripping from the indoor head of a mini split. Before you start, switch the unit off at the remote and, if you plan to open the cover, shut o - Poor capacity / high head
A mini split with poor capacity and high head pressure usually has a heat-rejection problem, so before assuming a refrigerant fault, confirm both coil - Water leaking
Water leaking from a mini split indoor head. I see this all the time, and it's almost always a drain issue: plugged line, dead condensate pump or a pa
Carrier (189)
- 24K/36K/48K: evaporator and refrigerant sensor removal
Removes the pipe clamp board, refrigerant sensor, evaporator fixing board and then the evaporator with its hangers. - 24K/36K/48K: fan motor and fan removal
Removes the fan and then the fan motor from the indoor unit. - 24K/36K/48K: water collector and water level switch removal
Removes the water collector and water level switch from the indoor unit. Ventilation ring and collector are removed first, then the level switch is ta - 24K/36K/48K: water pump removal
Removes the external water pump box assembly from the indoor unit. - 485 communication fault (S1, S2)
Communication between the indoor and outdoor main PCBs over the 485 signal wires fails. - Air filter cleaning
Filter cleaning procedure from the owner's manual. Removal and maintenance are to be done by a certified technician. - Automatic shutoff and protection features
The unit has several built-in protections. Know these before you troubleshoot so you can tell a protection trip from a real fault. - Built-in protections and special features
The indoor unit provides automatic restart after power loss at the same operating conditions, indoor coil freeze protection, and indoor coil high-temp - Buried refrigerant piping limits
Buried line length is limited to prevent refrigerant migrating to a cold buried section and causing slugging at start-up. - Ceiling cassette panel installation
Fit the one-way cassette panel into the ceiling opening and connect the display board. - Charging a flammable refrigerant system
Charge carefully and check for leaks before handover. - Choose the indoor unit installation location
Pick a location that has room for install and service, room for the refrigerant and drain piping, and a level ceiling that can hold the unit's weight. - Choosing the indoor unit location
Pick a site that has enough room for installation, maintenance, piping and drain. Do not install in the locations listed. Confirm the ceiling is level - Choosing the unit size and location
Select equipment that matches or slightly exceeds the peak load to improve humidity control and reduce cycling. For high sensible loads, size on sensi - Clean the indoor air filter
Dirty filters can reduce cooling, cause intermittent operation, frost on the indoor coil or blown fuses. Clean the filter every two weeks. - Coil cleaning
Clean the coil at the start of each cooling season or when needed. - Compressor winding check
Reference winding resistances for the inverter compressor models. Readings in the text are listed without a reliable column-to-row match, so verify ag - Condensate drain and removal
Drain must meet local plumbing codes. Indoor units have an internal trap, so no external trap is needed. Drain connections can be routed through alter - Connect refrigerant pipes and insulate
Connect the low-pressure line first, then the high-pressure line. Do not let any other gas or substance enter the unit. - Connect the indoor drain hose
Attach the drain hose to the indoor unit outlet and secure it so it cannot pull loose. - Control system sensors and operation
The indoor unit has a microprocessor control board that provides system safety and controls comfort and efficiency. Thermistors sit in the indoor unit - Cut, deburr and flare refrigerant pipe
Prepare the copper line set for flare connections. - Cut, deburr, flare and connect refrigerant pipes
Prepare the line set and connect it to the indoor unit first, then the outdoor unit. - Decommissioning and refrigerant recovery
Steps for emptying a flammable refrigerant unit before it is removed or scrapped. - Dehumidification (DRY) mode behavior
DRY mode dries, filters and slightly cools the room air. It prioritizes dehumidification but does not replace a dehumidifier. Humidity is adjustable f - Discharge capacitors before troubleshooting
Capacitors keep a charge after power is off. They must be discharged before any board work. - Display board removal
Removal of the display board on the D5FCFAH indoor unit. - Display shows a strange code or does not answer the remote - DLFSHB indoor
The indoor display on a Carrier DLFSHB high wall unit shows something that is not in the code tables, or the unit does not answer the remote. Before r - Drill the wall hole and set the drain route
Route the drain so water flows away from the unit with no sagging. - Drill the wall hole for piping
The hole must slope so the outdoor end is lower than the indoor end. This lets condensate drain outward. Avoid wires, plumbing and other sensitive par - Drill the wall penetration
Make a sloped wall hole so the drain and piping leave with proper fall. - Dust is emitted from indoor or outdoor unit
Dust that built up during long periods of non-use is released when the unit is turned on. This is normal. Covering the unit during long inactivity red - Dust or bad odor from the unit
Dust can be emitted after a long period of non-use. Odors can be absorbed from the room (furniture, cooking, smoke) or come from moldy filters. - Dust or bad odour from the unit
Dust can collect during long periods of non-use and is released when the unit starts. Odours can be absorbed from the room. Mouldy filters should be c - Dust released from indoor or outdoor unit
Dust comes out when the unit is turned on. - Electrical component checks on flammable refrigerant systems
Make sure no electrical fault could cause ignition before power is restored. - Electrical isolation before service
Basic lockout requirement before installing, modifying or servicing the system. - Electrical main board removal (indoor unit)
Remove the electronic control box cover and pull out the main board. Anti-static gloves must be worn. - Electrical wiring precautions
Electrical work must meet local and national codes. Keep the power supply, grounding and signal wiring separate and connected firmly. - Erratic, unpredictable or unresponsive operation
Interference from cell phone towers or remote boosters can cause malfunction. - Error code appears on the indoor unit display
For codes beginning with E, P, F, EH, EL, EC, PH, PL or PC, the unit may stop or keep running safely. Use this procedure first. - Error code display prefixes
When an error appears in the indoor unit window, it begins with E, P or F, followed by an extra letter and digits, as in E(x), P(x), F(x), EH(xx), EL( - Evaporator removal (indoor console unit)
Disassembly sequence for the indoor evaporator, including the sensor, water collector and stepper motor. - Evaporator temperature protection (frequency limit)
When the evaporator temperature gets too high, the compressor frequency is limited in steps. Figure 30 lists the TP steps and the T4 thresholds, but t - Evaporator temperature protection in cooling and heating
In cooling, when the evaporator temperature falls below the setting value the compressor stops. In heating, when the indoor coil is cold the anti-cold - Fan and motor removal
Procedure to remove the fan motor and fan assembly. There are two motor covers. - Fan and motor removal (indoor console unit)
Disassembly sequence for the indoor fan and fan motor on the D5FCFAH console unit. - Fan motor check (indoor DC motor and outdoor DC motor)
Checks for DC fan motors. Indoor motors have the control chip inside the motor. Outdoor motors have the control chip on the outdoor PCB. - Fan motor removal (indoor floor console unit)
Access and remove the fan motor and fan assembly from the indoor unit. - Fan Only indicator on (cooling-only models)
Outdoor temperature is very cold and anti-freeze protection is running to defrost the unit. This is normal operation. - Fan speed out of control protection
Indoor fan below 300 RPM for 50 seconds shuts the fan off and it restarts 30 seconds later. After three restarts the unit stops and the LED shows the - Field wiring between indoor and outdoor units
Power and communication run between the indoor and outdoor units. The main power feeds the outdoor unit, and the link to the indoor unit carries power - Filter and air grille panel removal
Disassembly of the indoor unit air grille, filter and front panel. - Filter cleaning
Remove and clean the air filters about once a month. Replace torn or excessively worn filters. Carbon filter can be washed with water every 6 months; - Filter removal
Procedure to remove the indoor unit air filter. - Final tubing check before charging
Confirm factory tubing on both indoor and outdoor units has not shifted in shipment. - General troubleshooting approach for indoor and outdoor units
Use the indoor unit display first. The outdoor display only shows a few errors. Errors show as a flashing operation lamp, possibly a lit or flashing t - Hang the ceiling/floor indoor unit
Mount the indoor unit on four suspension bolts. Two people are needed to lift it. - Heating output drops at low outdoor temperature
As outdoor temperature falls, HEAT performance drops. - Indicator lamps keep flashing
Indicator lamps continue to flash. - Indicator lamps keep flashing or an error code shows on the indoor display
Error codes on the indoor display start with E, P or F followed by letters or numbers. The unit may stop or keep running safely. - Indicator lamps keep flashing or error code shown on indoor display
Indoor display shows a code starting with E, P or F (for example E(x), P(x), F(x), EH(xx), EL(xx), EC(xx), PH(xx), PL(xx), PC(xx)). The unit may stop - Indicator lamps keep flashing or error codes appear
The unit may stop or keep running safely when lamps flash or codes show. - Indicator lamps keep flashing or error codes appear on indoor display
The unit may keep running safely. Error codes on the indoor display begin with E, P or F, such as E(x), P(x), F(x), EH(xx), EL(xx), EC(xx), PH(xx), PL - Indoor and outdoor units emit white mist
When the unit restarts in HEAT mode after defrosting, moisture from the defrost cycle can produce white mist. This is normal. - Indoor and outdoor units emit white mist after defrost in HEAT
Moisture from the defrost cycle can produce white mist when the unit restarts in HEAT mode. This is normal. - Indoor and outdoor units make noises
Low hissing during operation, or when starting, stopping or defrosting, is refrigerant flow and is normal. Squeaking from thermal expansion and contra - Indoor fan speed out of control
Indoor fan speed stays below 300 RPM for 50 seconds. The fan shuts off and restarts 30 seconds later. If this happens three times during restarts, the - Indoor fan speed out of range
Fault detection: if fan speed is below 300 RPM or above 1500 RPM for a set time, the unit stops and the LED shows a failure. - Indoor panel disassembly (09K/12K/18K)
Access the electronic control box and display board on the 09K, 12K and 18K indoor units. - Indoor unit emits white mist
In humid areas, a large difference between room air and conditioned air temperature can cause white mist. This is normal. - Indoor unit error display check
How to read an error from the indoor unit when no clear code is shown. - Indoor unit front panel cleaning
Clean the outside of the indoor front panel. - Indoor unit makes noises
A rushing air sound can occur when the louver resets. Squeaking when off or in COOL, or when the optional drain pump runs, is normal. Squeaking after - Indoor unit mounting height and room limits
Height and room size requirements for R-454B units. - Indoor unit or both units emit white mist
White mist is coming from the indoor unit, or from both units. - Indoor unit power wiring at the circuit breaker box
Open the control and breaker boxes, connect supply wiring to the breaker and bond the ground. - Indoor unit signal and power wiring
Prepare and land the signal and power cables at the indoor terminal block. - Indoor unit wiring
Wire the signal and power cables to the indoor terminal block, following the diagram on the control box cover. - Indoor units mode conflict (multi outdoor unit match)
Indoor units cannot run COOLING and HEATING at the same time; HEATING takes priority. If one indoor unit is in COOLING or FAN and another is set to HE - Indoor units mode conflict in multi-zone systems
Indoor units cannot run cooling and heating at the same time. Heating has priority. A unit in cooling or fan mode will switch off or go to standby whe - Indoor, outdoor or both units make noise
The unit makes sounds during operation. - Install the indoor drain line
Set up the drain so water runs away from the unit and cannot flow back. In HEAT mode the outdoor unit also discharges water, so keep the hose where it - Inverter module (IPM) continuity check
Check the IPM module with a diode-style continuity test on the outdoor board. - Inverter module automatic shutoff
The inverter module shuts the unit down when current, voltage or temperature goes out of range. The indoor display shows the corresponding error code. - Inverter module or discharge temperature shutoff
The inverter module shuts off on abnormal current, voltage or temperature, and the compressor stops when discharge temperature stays high for 9 second - Inverter module protection trip
The inverter module protects against current, voltage and temperature faults. When one engages, the matching code shows on the indoor unit and the uni - IPM continuity check
Checks the IPM module by measuring diode-type resistance between the module terminals. Electricity can stay in the capacitors after power-off, so disc - Leak checking a system with flammable refrigerant
Find refrigerant leaks without any ignition source on a flammable refrigerant system. - Leak detection on flammable refrigerant systems
Do not use a naked flame to find leaks. Electronic detectors may need recalibration for flammable refrigerants. - Long period of non-use and pre-season checks
Steps to take before storing the unit for a long time and before the start of the next season. - Long period of non-use and pre-season inspection
Prepare the unit before storage and check it before heavy use. - Long periods of non-use and pre-season inspection
Checklists for long non-use periods and before frequent use again. Figures 24 and 25 show the tasks. - Lower air outlet frame, refrigerant sensor and lower stepper motor removal
Procedure to remove the lower air outlet frame assembly, the refrigerant sensor and the lower stepper motor. - Main control board and electronic control box removal
Remove the panel first. Wear anti-static gloves. Steps 1 to 4 are for the main control board only; steps 5 and 6 are for the full electronic control b - Mark the mounting plate and wall hole
The wall hole size depends on the gas-side pipe size. A gas line of 5/8 in (16 mm) or larger needs a 3.54 in (90 mm) hole. A gas line smaller than 5/8 - Measuring voltage on control boards
Measuring live signals on the board requires the power on. Follow the sequence below and keep the probes correct. - Mount the wireless remote holder
Wireless remote holder is wall-mounted at a customer-selected spot within operating range. - Multi-zone: one room heats, another will not cool - DLC multi-zone
Here is one that confuses customers all the time on Carrier multi-zone systems with DLCM(R/H)B outdoor units and DLFSHB high wall heads. One room is h - Normal mist, sounds, dust and odor
These are common and usually not faults: white mist in humid conditions or after defrost in HEAT mode, rushing or squeaking sounds from the louver or - Normal noise, mist, dust and odor during operation
These conditions are normal for this unit and do not need service. - Normal noises from indoor and outdoor units
Several noises are normal: rushing air when the louver resets, squeaking from plastic or metal expansion and contraction, low hissing from refrigerant - Normal noises from the indoor and outdoor units
Several noises are normal: rushing air when the louver resets, squeaking from plastic parts expanding or contracting, squeaking from the optional drai - Normal operation: fault-free behaviors (Table 6)
Behaviors that are not malfunctions and usually need no repair. - Normal sounds, mist, dust and odor (not faults)
These conditions are normal and usually need no repair: white mist in humid conditions or after defrost, rushing or squeaking when the louver resets o - Opening the refrigerant circuit and recharging (flammable refrigerant R-454B)
Only trained and certified technicians may open the refrigerant circuit. Make sure the area is ventilated and there are no ignition sources before wor - Opening the refrigerant circuit for repair
Sequence for breaking into a flammable refrigerant circuit. - Operating modes and priority
The unit has FAN Only, AUTO, HEATING (heat pump models only), COOLING and DEHUMIDIFICATION (DRY) modes. HEATING is the priority mode, and simultaneous - Operation and PRE-DEF lights on, or FAN indicator on (cold outdoor conditions)
With the Operation and PRE-DEF indicators lit on a cooling and heating model, the outdoor unit is in anti-cold-wind defrost. On a cooling-only model w - Operation is erratic or the unit does not respond
Interference from cell phone towers or remote boosters can cause malfunction. - Operation is erratic or unit does not respond
Interference from cell phone towers or remote boosters may cause malfunction. - Operation light and PRE-DEF indicator lit, or Fan Only lit
On cooling and heating models, the Operation and PRE-DEF lights together mean the outdoor temperature is too cold and anti-cold wind is active to defr - Operation light and PRE-DEF indicators on (cooling and heating models)
Outdoor temperature is very cold and the anti-cold wind function is running to defrost the unit. This is normal operation. - Operation light and PRE-DEF or Fan Only indicator lit
In cooling and heating models, the Operation and PRE-DEF lights mean the outdoor temperature is cold and the anti-cold wind function is defrosting the - Outdoor fan does not run
Outdoor fan speed is controlled during operation to optimize performance, so the fan may not run continuously. This is normal. - Outdoor fan not running
The outdoor fan speed is controlled automatically to optimize operation, so the fan may stop or run slowly. - Outdoor fan speed out of control
Outdoor fan speed stays below 100 RPM or above 1500 RPM for 60 seconds. The unit stops and the LED shows the failure. The fault clears 30 seconds late - Outdoor unit fan does not operate
During operation the fan speed is controlled automatically to optimize unit performance. Fan stopping or changing speed is normal. - Outdoor unit fan does not run
The outdoor fan stops or runs at varying speeds. - Outdoor unit makes noises
The outdoor unit sounds differently depending on its current operating mode. This is normal. - Panel frame subassembly removal
Procedure to remove the panel frame. - Parts to replace by PC code (outdoor PCB matrix)
Matrix of outdoor parts that may need replacement for each PC code: outdoor PCB, outdoor fan motor, T3 sensor, TP sensor, pressure sensor, reactor, co - Poor cooling performance
The unit cools less than expected. - Poor heating performance
The unit heats less than expected. - Power and communication wiring between indoor and outdoor units
Power and communication run from the outdoor unit to the indoor unit as four conductors. The wiring is polarity sensitive. - Prepare refrigerant pipe ends (cut, deburr, flare)
Clean, square and properly flared ends are needed for an airtight joint. Only the specified refrigerant may go into the system. - Preparing for extended shutdown
Steps before leaving the unit off for a long period. - Pressure and vacuum test of field piping
Test field piping after install and before charging. The tightness test for indoor joints uses a sensitivity of 5 g/year. - Pressure test and evacuation of field refrigerant piping
Field piping must be pressure tested with inert gas and vacuum tested before charging. - Protective shutdowns on condenser and evaporator temperature
Compressor stops when condenser temperature exceeds the configured value. On heat pumps, evaporator coil protection stops the compressor or lowers fre - R-454B (A2L flammable refrigerant) field piping, leak test and charging requirements
Requirements for field-made refrigerant work on this A2L flammable refrigerant system. Only trained and certified service personnel should work on the - Recovering and decommissioning a flammable refrigerant system
Only competent, certified technicians should decommission. Oil and refrigerant samples should be taken first if reuse may be needed. - Refrigerant leak code response
Applies to the refrigerant leak detection codes in Table 9 (ECC1, EHC1, EHC2, EHC3, FHCC). - Refrigerant leak detected (units with sensor)
On units with a refrigerant sensor, a detected leak makes the indoor unit show an error code and buzz. The outdoor compressor stops right away and the - Refrigerant leak detected by indoor unit sensor
On units with a refrigerant sensor, a detected leak makes the indoor unit show an error code and buzz. The outdoor compressor stops straight away and - Refrigerant leak detected by sensor
When the leak sensor detects refrigerant, the indoor unit shows an error code and buzzes, the outdoor compressor stops immediately, and the indoor fan - Refrigerant leak detected by the sensor
On units with a refrigerant sensor, a detected leak makes the indoor unit show an error code and beep. The outdoor compressor stops right away and the - Refrigerant leak detection alarm (EHC/ECC codes)
A refrigerant leak code is shown. The unit switches to TURBO mode until the code clears. - Refrigerant leak detection response (EHC1, EHC2)
A refrigerant leak code means the unit needs a technician soon. The unit runs in TURBO mode until the code clears. A beeping from the indoor unit is n - Refrigerant leak detection system operation
On units with a refrigerant sensor, a detected leak shows an error code on the indoor unit and sounds a buzzer. The outdoor compressor stops immediate - Refrigerant leak sensor response (indoor leakage sensor)
On detection of a leak the outdoor unit shuts off, indoor fan runs turbo, louvers fully open, and an audible alarm sounds. In single-zone systems the - Refrigerant leak shutdown - multi-zone
The outdoor unit shuts off, the emergency shutoff valve closes, all EEVs close, and all indoor units run at turbo fan speed. The unit detecting the le - Refrigerant leak shutdown - single-zone
When a leak is detected the outdoor unit shuts off, the indoor fan runs at turbo speed, the louvers fully open and an audible alarm sounds. Codes EHC1 - Refrigerant line installation
Refrigerant lines can exit from the left, right or back of the unit. Both refrigerant lines must be insulated. - Refrigerant recovery, purge and evacuation before opening circuit
Required sequence for flammable refrigerant work on the circuit. - Remote control battery replacement
Two AAA alkaline batteries are needed for the remote. - Remote control does not respond
Remote commands are not reaching the unit. Batteries or distance are the usual causes. - Remote control quick start
Basic operation from the wireless remote. The unit confirms each command with a beep. Point the remote toward the right side of the unit when sending - Removing refrigerant and evacuating before opening the circuit
Follow this order when breaking into the refrigerant circuit. - Replace board fuse
The PCB fuse specification is printed on the board (for example T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC, T30A/250VAC). Onl - Select piping exit direction and knock-out panel
Four exit directions are available: left-hand side, left rear, right rear, and right-hand side. The drain hose is recommended on the right-hand side w - Service procedure for flammable refrigerant (R-454B)
Required practice when working on a system that contains A2L flammable refrigerant R-454B. - Servicing a system with flammable refrigerant R-454B (A2L)
Safety requirements from the manual for work on R-454B circuits. Follow national and local codes. - Single temperature sensor fault or multiple sensor faults
One failed temperature sensor: the unit keeps running for emergency use and shows the matching error code. More than one failed sensor: the unit stops - Start-up checklist: electrical, piping and charge checks
Items the start-up checklist asks the technician to verify and record for a single-zone ductless system. - Start-up leak check and evacuation
Piping checks to complete during start-up of the ductless system. - Stop the unit immediately
Stop operation at once if the power cord is damaged or warm, there is a burning smell, loud or abnormal sounds, a fuse blows or breaker trips often, o - Stop the unit immediately if these occur
Switch off the unit at once if the field wiring is damaged or abnormally warm, a burning smell occurs, the unit makes loud or abnormal noises, a fuse - Stop using the unit immediately
Turn the unit off immediately if any of these occur: field wiring is damaged or abnormally warm, a burning odor is present, the unit makes loud or abn - System evacuation and charging
Evacuate tubing and indoor coil with a 500 micron deep vacuum, or use the triple evacuation method if the pump cannot reach 500 microns and the system - Temperature sensor check
Measure a temperature sensor's resistance and compare it with the Appendix table. - Temperature sensor fault
If one temperature sensor malfunctions, the unit keeps running for emergency use and shows the matching error code. If more than one sensor is faulty, - Temperature sensor faults
If only one temperature sensor fails, the unit keeps running and the error code shows on the LED for emergency use. If more than one sensor fails, the - Temperature sensor open or short circuit check (EH60, EH61, EH62, EH65, EH66, EC52, EC53, EC54, EC56)
A sensor is faulty when the sampled voltage is below 0.06 V or above 4.94 V. - Turn the unit off immediately if these occur
Stop the unit at once if the power cord is damaged or abnormally warm, there is a burning odor, loud or abnormal sounds, a power fuse blows or the bre - Two dashes (--) on the indoor display in multi-zone AUTO
AUTO CHANGEOVER on multi-zone systems can put an indoor unit in STANDBY. Standby is shown as two dashes and turns that unit off until all units match - Unit changes from COOL or HEAT mode to FAN mode
The unit may switch to fan mode to stop frost forming, or because the set temperature was reached and the compressor turned off. It returns to the sel - Unit changes from COOL or HEAT to FAN mode
The unit may switch to FAN mode to prevent frost forming on the unit, or because the set temperature was reached and the compressor turned off. - Unit changes from COOL or HEAT to FAN, or compressor stops
This is normal. The unit may switch to FAN to stop frost forming, or stop the compressor when the set temperature is reached. It returns to the select - Unit changes from COOL/HEAT to FAN mode
The unit may switch to FAN mode to stop frost forming. It may also switch when the set temperature is reached and the compressor stops. - Unit does not start in COOLING mode
COOLING will not start if the set point is above room temperature. Mode and temperature must be set so the unit can run. - Unit does not start right after being stopped
The compressor has built-in protection against frequent cycling, so a restart soon after a stop is delayed. - Unit does not start when ON/OFF is pressed
The unit has a 3-minute protection feature to prevent overloading. It cannot restart within three minutes of being turned off. - Unit does not turn on when ON/OFF is pressed
The unit has a 3-minute protection feature that stops it from overloading. It cannot restart within three minutes of being turned off. - Unit does not work
Unit or system does not run. - Unit emits a bad odor
The unit can absorb room odors such as cooking, smoke or furniture and release them during operation. Moldy filters also cause odor. - Unit is not working
The unit does not run at all. - Unit is not working (no output)
Unit does not respond or heat is absent. - Unit starts and stops frequently
The compressor cycles on and off more often than normal. - Unit stops during operation
Unit shuts off while running. - Unit turns off immediately: shut-down conditions
Stop the unit and call a service provider if any of these occur: power cord damaged or abnormally warm, burning odor, loud or abnormal sounds, fuse bl - Upper air outlet frame and upper stepper motor removal
Procedure to remove the upper air outlet frame assembly and the upper stepper motor. - Voltage check at outdoor and indoor units
Measure voltage at the outdoor disconnect, outdoor terminal block and indoor unit during start-up. - Voltage checks at start-up
Check voltages at the outdoor disconnect, outdoor terminal block and indoor unit before running the system. - Water discharge (drain) test
Checks that the condensate drain works before the ceiling is closed. Run it in the new room before the ceiling is finished. - White mist from indoor or outdoor unit
White mist can be normal. The indoor unit can emit mist in humid regions when there is a large temperature difference. Both units can emit mist after - Wiring the indoor unit to the outdoor unit and controller
Use the wiring diagram label on the actual unit. The printed diagram on this page is largely unreadable. - Work area checks before opening a flammable refrigerant circuit
R454B is flammable. Make the area safe before any work that opens the refrigerant circuit or involves hot work. - Zero crossing detection error
If the zero crossing interval is wrong for a continuous 240 s, the unit stops and the LED shows the failure. The correct interval is between 6 and 13
Daikin (55)
- 2-Area INTELLIGENT EYE detection and energy saving
Applies to FTXM09/12WVJU9 and FTXM09/12VVJU. The motion sensor splits the room into 2 areas. If no one is present, capacity is reduced to save power. - Air has an odor
Unit gives off a smell during operation. - Call the dealer immediately
Symptoms that require stopping the unit and calling the dealer. - Check compressor and inverter with the analyzer
Tell a bad compressor from a bad board. Tool is analyzer RSUK0917C. - Check expansion valve
Connector S20 test. - Check outdoor fan motor
Voltage test at connector S70. - Check power module and diode bridge for shorts
Resistance checks on a de-energized unit. - Check the work area before refrigerant work on R-32 units
R-32 is mildly flammable. Make the area safe before opening any refrigerant part. - Check thermistors by resistance
Resistance chart, 20 kohm at 25 C (77 F), B 3950 K. - CLEAN operation indicator lamp behavior
The LCD CLEAN lamp depends on whether the unit is running and whether CLEAN is set. While running with CLEAN on, the CLEAN lamp is lit. While running - Connect the thermostat to Wi-Fi
Setup of the Wi-Fi connection to the Daikin One Cloud. - Discharge pipe thermistor disconnection control
Disconnection is found by comparing the discharge pipe temperature with the condensing temperature (outdoor in cooling, indoor in heating) after start - Discharge the outdoor unit capacitor before repair
The outdoor unit has a step-up capacitor that holds high-voltage charge. It can shock you even after the unit is off. - Display lamps on main unit are dark
Indoor unit lamps are dim. - Dry operation: room temperature zones, fan and expansion valve control
In dry mode the room temperature zone sets the fan tap. Airflow cannot be set manually, and fan speed also responds to room humidity. Fan speeds in dr - EEV high discharge pipe temperature control
When the compressor runs and discharge pipe temperature exceeds a set value, the expansion valve opens and sends refrigerant to the low pressure side. - Electronic expansion valve (EEV) control overview
The valve is fully closed at power on. It opens for pressure equalizing when the compressor is off, and for starting control, frequency changes, defro - Force cooling for testing
Run the unit without waiting on thermostat. - Freeze-up protection control (cooling)
In cooling, the signal from the indoor unit sets the compressor frequency upper limit so the indoor heat exchanger does not freeze. The signal is spli - H8 check flow (DC voltage/current sensor)
Flowchart for H8. Some branch text in the page scan is out of order, so follow the decision points as listed here and check the referenced checks (No. - Heating peak-cut control
In heating, the indoor heat exchanger temperature sets the compressor frequency upper limit to prevent abnormally high pressure. Stop zone: compressor - High pressure protection control
To avoid tripping the high pressure safety device, the control acts when high pressure safety (HPS) reaches 4.15 MPa or more while the compressor is o - Indoor fan speed control (automatic fan setting)
Fan has 9 steps: LLL, LL, SL, L, ML, M, MH, H and HH (HH is POWERFUL). With FAN set to automatic, the airflow is chosen from the gap between room ther - Indoor operation lamp blinking every 0.5 seconds
The lamp flash means a fault is stored. - INTELLIGENT EYE energy saving behaviour (FTXM09 / FTXM12 2-area)
Explains why the unit may change setpoint or the INTELLIGENT EYE lamp may go off. - Internet connected but no cloud connection
The menu offers a restart option when internet is connected but the Daikin One Cloud is not. - Lightning risk
Storm risk can damage the system. - Liquid compression protection (low outdoor temperature cooling)
The compressor is turned off in cooling operation when the outdoor temperature is below 0°C (32°F), to protect against liquid compression. - Loud noise or vibration from outdoor unit
Excess noise or shaking. - Mist or water comes from the indoor unit
Mist can appear during cooling. Water leaking from the unit needs a dealer. - No air from the indoor unit at start-up
Indoor unit does not blow air right after operation starts. - Open an R-32 refrigerant circuit safely
Follow this order whenever the refrigerant circuit must be broken for a repair. - OPERATION lamp off while the unit runs
Unit is running but the OPERATION lamp is dark. - Other electric devices switch on with the remote
The remote controller activates other appliances. - Outdoor LED A not blinking
Outdoor PCB health light. - Post-repair electrical and drainage checks
Checks to finish with before handing the unit back. - Pre-trial-run installation checks
Check each item before the trial run. The listed symptom is what happens if the item is missed. - Pump down before moving or scrapping the unit
Recover refrigerant into the outdoor unit. - Read fault codes from the remote, method 1
Quick way to pull a stored code on the ARC466A37. - Read fault codes from the remote, method 2
Full service check mode on the ARC466A37. - Recharge refrigerant on R-32 units
Charging rules that apply on top of normal charging practice. - Recover refrigerant and decommission the unit
Recovery and decommissioning steps for R-32 units. Take an oil and refrigerant sample first if the recovered refrigerant may be reused. - Remote controller has no signal or short range
Indoor unit does not respond to the remote controller. - Remote LCD faint, blank, or erratic
Remote display is dim, not working, or flickering. - Remote shows blinking battery icon and does not operate
Battery power is exhausted and the remote cannot send commands. - Room does not cool or warm enough
Air flow is present but the room does not reach the set temperature. - Runs but does not cool or heat
Compressor runs but the room does not change. - Sensor malfunction detection
The control checks these thermistors for malfunction: outdoor heat exchanger thermistor, discharge pipe thermistor, radiation fin thermistor and outdo - Target discharge pipe temperature control
The target discharge pipe temperature comes from the indoor and outdoor heat exchanger temperatures. The expansion valve opening is adjusted every 20 - Thermostat ON/OFF control logic
Thermostat control uses the difference between room thermistor temperature and target temperature, split into zones A, B and C. Thermostat OFF happens - Unit behaves strangely during operation
Sudden odd behavior, possibly from lightning or radio interference. - Unit does not run at all
Nothing starts from the remote or the unit switch. - Unit stops now and then
Operation drops out at times. - Unit stops when operating outside the listed range
Operation outside the listed temperature range triggers protection. - Weekly timer or ON/OFF timer does not follow settings
Timer programs conflict when set to the same time.
Midea (2)
- Display shows a strange code or does not answer the remote - DLFSHB indoor
On Midea DLFSHBH high wall indoor units (09-24K) on DLC multi-zone or single-zone outdoor units, the display sometimes shows what looks like a code th - Multi-zone: one room heats, another will not cool - DLC multi-zone
Multi-zone Midea DLC: one room heats, the other will not cool. Not a fault. Indoor units on one outdoor unit cannot heat and cool at the same time. Co
Viessmann (147)
- Attach the mounting plate to the wall
The mounting plate carries the indoor unit and must be level before the unit is hung. - AUTO mode operation
Setpoint can be changed between 62.6 F (17 C) and 86 F (30 C). The unit picks COOLING, HEATING or FAN ONLY from DT (T1 minus Ts). Not recommended when - Both indoor and outdoor units emit white mist
When the unit restarts in HEAT mode after defrosting, moisture from the defrost cycle can produce white mist. This is normal. - Bundle and wrap piping, drain hose and signal cable
Bundle the lines so the drain stays low and the line ends stay open for leak testing. - Check supply voltage on single-zone system before start-up
Measure voltages at the outdoor disconnect, outdoor terminal block, and indoor unit, then record on the checklist. - Choosing the indoor unit location
Pick a spot with clear space around the inlet and outlet, a wall or floor that can carry the unit's weight, and no direct sun or nearby heat source. K - Clean the air filters (monthly)
Clogged filters cut cooling efficiency and can damage the indoor unit. Dusty sites need more frequent cleaning. - Clean the front panel
Keep water temperature and cleaners within limits to avoid damage. - Clean the indoor coil
Clean at the start of each cooling season or when needed. Fins are very sharp. - Communication line DC voltage and reactor check
Used with EL 01 to decide whether the indoor or outdoor side has failed. - Communication line DC voltage check (indoor to outdoor)
Used with EL 01 to check the signal between the indoor and outdoor units. - Compressor check and IPM continuity check
Check the compressor windings and the IPM (power module) with a digital tester. The IPM continuity values in Table 11 are not legible on the scanned p - Condensate drain and lift pump limits
The factory condensate lift pump is on the ducted fan coil. Install the drain to local sanitation codes and do not exceed the maximum lift. - Condensate drain installation
The drain must slope downward along its full length and must not be exposed to freezing. Use a condensate pump where gravity drainage is not possible. - Connect and route the drain hose
The drain must slope and be free of kinks and traps so condensate runs out freely. - DC fan motor test (indoor and outdoor)
Checks whether the fault is in the fan motor or in the PCB. - Deep vacuum method
Requires a vacuum pump that can pull 500 microns and a gauge that reads that depth accurately. This is the most effective way to make sure the system - Diagnostic lights illuminate on unit
Diagnostic lights are combinations of the normal operating lights. The manual gives no code table on these pages. On cooling-and-heating models, the O - Display shows a strange code or does not answer the remote - DLFSHB indoor
Viessmann DLFSHB high wall indoor, 09-24K. Display shows an odd code not in the tables, or the unit ignores the remote. Check what the display is real - Distorted or unrecognised indoor display
Display shows a distorted code, a code not in the manual, or a value that is not a temperature reading. - Drill the wall hole for connecting piping
The wall hole must slope down to the outside so condensate drains properly. - Drilling the wall hole for piping, drain and wiring
Route the piping, drain and wiring through a wall hole with a slight downward slope, and keep the flare and drain connections on the outside of the wa - DRYING mode low room temperature protection
In DRYING mode, if room temperature is below 50 F (10 C), the compressor stops. It restarts only when the room rises above 53.6 F (12 C). Indoor fan i - Dust comes out of indoor or outdoor unit
Dust builds up during long non-use and is released when the unit is turned on. Covering the unit during long inactivity reduces this. - Dust comes out of the indoor or outdoor unit
Dust that built up during long periods of non-use is released when the unit is turned on. This is normal. - Dust or bad odor from unit
Dust builds up during idle time. Odors come from room air absorbed by the unit. - Electrical control box removal (18K Standard Heat)
Removes the electronic control box subassembly. Wear anti-static gloves when handling the electronic box. The box cover cannot be removed on this mode - Electrical main board removal
Removes the electrical main board from the indoor unit control box. Anti-static gloves must be worn. - Electrical parts removal, sizes 48K-58K
Steps to disconnect power and ground wires, remove the main control board and fan motor capacitors. Connections noted on the diagram: low and high pre - Electronic control board access, size 36K
Steps to open the control box and remove the electronic control board and key board on the terminal board. - Electronic control board and control box removal (24K High Heat, 30K Standard and High Heat, 36K Standard Heat)
Removes the electronic control box subassembly. The box cannot be opened on this model, so P to N voltage cannot be measured. - Electronic control box cover opening (18K High Heat, 24K Standard Heat)
Opens the control box cover. The cover cannot be removed on this model, so P to N voltage cannot be measured. - Evacuate and charge system with vacuum pump
Evacuate all circuits at once through the low side master service valve charge port. Break vacuum with dry nitrogen only. Factory charge in the outdoo - Evaporator coil over-temperature protection in HEATING
When the evaporator temperature rises above the protection setting, the compressor stops. - Evaporator low temperature protection (T2)
The compressor is limited or stopped when the evaporator pipe temperature (T2) is low. - Evaporator temperature protection in COOLING
When the evaporator temperature falls below the setting value, the compressor stops. - Extended shutdown preparation
Dries internal parts before the unit sits idle. - Fan and fan motor removal
Removes the fan motor and fan assembly from the indoor unit. The evaporator subassembly must come out first. - Field wiring between outdoor and indoor units
Power and communication wires run between the outdoor and indoor units. Wire size depends on the unit size. Wire must be sized to NEC/CEC and local co - Field wiring installation checks (indoor to outdoor unit)
Checks to make before energising the indoor and outdoor units. Power and communication run between the two units in one cable set. - Final system checks before handover
Check tubing, drain, insulation and the indoor unit functions before leaving the site. - Flare connection for interconnecting piping
Cut, deburr and flare the copper line, then torque the flare nut to the value in the table. Use refrigerant oil on the flare seat. - Front panel and filter access
Opening the front panel to reach the filter. Procedure continues beyond page 40 and is not fully shown here. - Hang the indoor unit on the mounting plate
Hook the unit on the plate and confirm it is secure before the pipe work is finished. - Hanging the indoor unit in the ceiling
Cut the ceiling opening and hang the unit on four suspension bolts. The unit must match the hole size before continuing. - Heating output drops in cold outdoor temperatures
As outdoor temperature falls, the HEAT function performance may be reduced. - How to read the cooling performance rows (TC, S/T, PI)
Each outdoor temperature row gives three printed values: TC, S/T and PI. The pages do not define these abbreviations, so confirm their meaning elsewhe - How to read the D5CSRA cooling performance matrices
Pages 64 to 72 hold cooling capacity matrices for the D5CSRA with different indoor units (the table titles on these pages cover 18K 4-way cassette and - Indoor and outdoor units emit white mist after defrost
Normal. Moisture from the defrost cycle is emitted when the unit restarts in HEAT. - Indoor and outdoor units make hissing noise
Normal refrigerant flow sound during operation, start, stop or defrost. - Indoor and outdoor units make noise
A low hiss during operation, or when starting, stopping or defrosting, is normal refrigerant flow. Squeaking from metal and plastic expanding and cont - Indoor and outdoor units make noise (hissing or squeaking)
Normal. Low hissing during operation is refrigerant flowing through both units. Low hissing at start, stop or defrost is refrigerant stopping or chang - Indoor fan delayed open at startup
On startup the louver moves right away and the indoor fan starts about 10 seconds later. In HEATING mode the fan is controlled by the anti-cold wind f - Indoor fan rules in HEATING mode
When the compressor is on, the fan can be set to high, medium, low, auto or mute. When coil temperature is low, the anti-cold air function runs the fa - Indoor fan speed out of control
The indoor fan speed stays too low. The unit shuts the fan off and retries. After three failed restarts the unit stops and the LED shows the failure. - Indoor fan speed too low
Indoor fan speed protection. Fan speed can drop below the minimum for a set time. - Indoor unit electrical connections
Connect the outdoor unit wiring to the indoor unit per the connection diagram. Refit the cover and sensor bearer after wiring. - Indoor unit emits white mist
Normal in humid areas when the room air and supply air differ widely in temperature. - Indoor unit makes noise
Usually normal. Squeaking can come from plastic parts expanding and contracting, and from the optional drain pump. - Indoor unit mounting and location checks
Mount the unit level in all planes and leave room for airflow. Keep the return and discharge free of furniture or curtains that could cause short cycl - Indoor unit shows two dashes (--) in a multi-zone system
In AUTO on a multi-zone system the indoor unit can drop into STANDBY and show two dashes. This is expected behaviour, not a fault. - Install interconnecting piping and wiring to the indoor unit
Run the lines from the outdoor unit to the indoor unit, hang the indoor unit, then make the flare connections. - Install interconnecting power, wiring and piping at the indoor unit
Sequence for running the outdoor-to-indoor wiring and piping, then connecting them at the indoor unit. - Install wired wall remote controller (801 kit)
Wire the 801 kit harness and multi-function board between the main board and display board. - Install wireless remote control holder
Mount the holder in the customer-selected location within remote operating range. - Inverter module protection
The inverter module protects against overcurrent, overvoltage and over temperature. If one engages, the matching code shows on the indoor unit and the - Main control board removal (36K High Heat, 48K Standard and High Heat, 60K Standard and High Heat)
Removes the main control board and the fan motor capacitors. Note the wiring to the IPM module board, the T3/T4 sensors, the low and high pressure swi - Maintain indoor unit clearances
Keep the required space around the indoor unit so return airflow and service access are not restricted. - Maintenance clearance and ceiling access panel sizing
Plan access for the indoor unit before mounting it above a fixed ceiling. - Make the refrigerant flare connections
Clean square cuts and correct torque are needed for leak-free flare joints. - Mounting size 12K console (floor console only)
Size 12K can only be mounted as a floor console, hung on wall hooks anchored into studs. - Mounting sizes 18K to 58K (floor console or underceiling)
These sizes can be floor mounted or installed underceiling using hanging screw bolts. - Multi-zone: one room heats, another will not cool - DLC multi-zone
Viessmann Vitocal 200-S multi-zone (DLCM(R/H)B outdoor with DLFSHB high wall heads): one room heats, another will not cool. Normal behaviour, not a fa - Operation light and PRE-DEF indicator on, or Fan Only indicator on (cooling-only models)
On cooling and heating models, the Operation light and PRE-DEF (pre-heating/defrost) indicator together mean the outdoor air is too cold and the anti- - Operation light and PRE-DEF indicators on (defrost in progress)
On cooling-and-heating models, the outdoor temperature is too cold and the anti-cold wind function is defrosting the unit. On cooling-only models, the - Outdoor fan speed out of control
The outdoor fan speed is either too low or too high. The unit stops and the LED shows the failure. The fault clears 30 seconds after the speed returns - Outdoor fan speed out of range
Outdoor fan speed protection. Unit stops if fan speed is outside the allowed band. - Outdoor unit fan does not run
Normal. Fan speed is controlled during operation to optimise performance. - Outdoor unit front right, front and right side panel removal (36K HH, 48K, 60K)
Panel removal order on the outdoor unit after the top covers are off. - Outdoor unit makes noise
The outdoor unit sounds differently depending on its current operating mode. Normal. - Outdoor unit makes noise or outdoor fan does not run
Sound changes with operating mode. Fan speed is controlled automatically during operation. - Outdoor unit panel removal (size 36 steps)
Panel and water collecting cover removal sequence shown on pages 39 to 41. The size is not printed on these pages; it is inferred from the continued s - Outdoor unit panel removal (sizes 48-58, with 36 panel steps)
Procedure to open the DLCLRC outdoor unit casing: handle, top cover, water collecting cover, front right panel, front panel and right panel. Steps 1-4 - Outdoor unit top and water collector cover removal (36K HH, 48K, 60K)
Disassembly sequence for the top covers and water collecting cover on the outdoor unit. Turn off power first. - PCB Board 8 key board removal
Removes the key board from PCB Board 8. - PCB Board 8 removal: IPM module board and 24V board
Removes the IPM module board and the 24V board. Wires to the DC fan motors, compressor and main control board are involved. - Performance tables, pages 24-29 (not fully transcribed)
Pages 24-29 hold cooling and heating capacity and input grids for cassette, ducted and floor/ceiling/console indoor units on 36K, 48K and 58K outdoor - Poor cooling performance
Check the common causes from the troubleshooting table before calling service. - Poor heating performance
Check the common causes from the troubleshooting table before calling service. - Power and communication wiring, sizes 12 to 24
Power is fed to the outdoor unit and runs to the indoor unit on a field-supplied 14/3 cable. Two conductors are high-voltage AC, one is communication, - Power and communication wiring, sizes 36 to 58
Power runs from the outdoor unit to the indoor unit on three conductors: two high-voltage AC and one ground, factory recommended 14/2 stranded with gr - Power supply and electrical safety before wiring
Verify supply and protection before making any field electrical connections. - Prepare the refrigerant piping exit
Choose the piping exit side and open the unit to route the lines. Do not kink or dent the piping. - Rain protection when outdoor unit is higher
If the outdoor unit sits higher than the indoor unit, rain can run down the connection pipe into the indoor unit. - Reading the diagnostic LEDs
The indoor unit has the main diagnostic display, shown as flashing lamps on the display panel or front of the unit. The outdoor unit board has only tw - Refrigerant line installation
Lines are shipped with R410A charge on the outdoor unit. Buried lines need limits and a rise at the service valves. - Refrigerant line set-up and charge
Rules for installing the line set between the outdoor and indoor unit. - Refrigerant pipe buried in the ground
Buried refrigerant pipe has length and rise limits. Too much buried pipe lets refrigerant migrate into the cold buried section during shutdown, which - Remote control does not respond
Check the remote and batteries before suspecting the indoor unit. - Remote control does not respond or no beep from indoor unit
The remote may have weak or exhausted batteries. Replace them before going further. - Remove display board subassembly
Display board removal. The left cover of the panel must be opened before starting. - Remove filter and front panel from one way cassette indoor unit
Front panel and filter removal on the DLFSOAH indoor unit. Panel removal differs depending on whether the panel has a lift function. - Remove main control board or electronic control box
Electrical parts removal. Remove the panel first. Anti-static gloves must be worn. Choose between repairing the main control board assembly (steps 1 t - Remove the display board and humidity sensor module
Access to the display board and the humidity sensor module on the indoor console unit. - Remove the evaporator and coil temperature sensor T2
Remove the panel, water collector and water pump first. T2 is the coil temperature sensor. Its ribbon must be cut and the ground screw removed. - Remove the evaporator subassembly
The front panel, panel frame and both air outlet frame assemblies must be removed first. - Remove the fan and fan motor
The evaporator subassembly must be removed first. The unit has two motor covers. - Remove the fan motor and fan
Remove the panel, electrical parts, water collector, water pump and evaporator first. The fan motor and fan come out as one assembly, and the motor ca - Remove the filter from the indoor floor console unit
Filter access on the DLFSFBH 12K indoor console. The front panel is opened first, then the filter is pulled out. - Remove the lower air outlet frame assembly and lower stepper motor
Front panel and panel frame subassembly must be removed first. - Remove the panel frame subassembly
Removes the panel frame of the indoor console unit. - Remove the positive and negative ion generator
Ion generator and ion emitter removal from the upper air outlet area. The panel must be removed before the electronic control box is serviced. - Remove the stepper motor
Remove the panel first. Open the louver and release the hooks to reach the motor cover. - Remove the upper air outlet frame assembly and upper stepper motor
Front panel and panel frame subassembly must be removed first. - Remove the water collector
Take the front panel off before removing the water collector. The collector is held by five screws. - Remove the water pump
Remove the panel and water collector before starting. The pump is held by two screws and has a spring and a drain pipe to release. - Remove water collector
Water collector removal. Remove the panel before starting this procedure. - Select the indoor unit installation location
Pick a wall location that allows good airflow, drainage and piping access, and avoid heat, moisture and electrical interference. - Set external static pressure or run automatic airflow adjustment
Setting the fan performance to match the ducts, using the wired controller. - Set static pressure or automatic airflow with the wired controller
Use the wired controller (KSACN0701AAA) to pick a fan curve SP1 to SP4 or run automatic airflow (AF) for the duct system. Confirm the coil is dry firs - Shut off power and call the dealer
Stop the unit and get service if any of these occur. - System checks before handover
Check the tubing, drain and insulation, then confirm the indoor unit functions. - Temperature sensor check
Check a temperature sensor by measuring its resistance with the sensor unplugged from the PCB. Compare the reading with the sensor resistance table in - Temperature sensor identification
The unit uses five temperature sensors: room (T1), indoor coil (T2), outdoor coil (T3), outdoor ambient (T4) and compressor discharge (T5). Test each - Temperature sensor open or shorted
If only one temperature sensor fails, the unit keeps running in emergency use and the error code shows on the LED. If more than one sensor fails, the - Temporarily bypass the 24V interface to set static pressure
With a 24V interface installed, the wireless remote, wired controllers and Wi-Fi kit are disabled. The interface must be bypassed to use the wired con - The unit is not working
Check these points before calling a repair company. - Triple evacuation method
Alternate evacuation method when it is followed exactly. Always break the vacuum with dry nitrogen. - Unit cannot be restarted right after being turned off
The unit will not restart within three minutes of being switched off. This is the built-in three-minute protection. - Unit changes from COOL or HEAT mode to FAN mode
Normal behaviour. The unit may change mode to prevent frost forming on the unit, then resume the selected mode once temperature rises. It also changes - Unit changes from COOL or HEAT to FAN mode
This is normal operation. In heating, the unit may switch to fan mode to stop frost forming on the outdoor unit. In either mode, it turns off the comp - Unit changes from COOL to FAN by itself
Normal operation. The unit may switch to FAN to prevent frost, or reach set point and stop the compressor. - Unit does not run or does not turn on
Common checks before calling service. The 3-minute protection is normal after a restart. - Unit does not turn on when ON/OFF is pressed
The manual lists no specific causes for this symptom. Also note that the unit cannot be restarted within three minutes of being turned off. - Unit emits a bad odor
The unit can absorb odors from the room, such as furniture, cooking or smoke, and release them during operation. Moldy filters also cause odor. - Unit emits a bad odour
The unit can absorb odours from the room, such as furniture, cooking or cigarettes, and release them when running. Moldy filters also cause odour and - Unit selection and indoor unit sizing
Size the indoor unit to match or slightly under the peak load. This improves humidity control, reduces cycling and limits part-load operation. In high - Unit selection and sizing
Match the unit to the peak load or go slightly below it for better humidity control and fewer cycles. - Unit starts and stops frequently
Check these points before calling a repair company. - Unit stops during operation
Usually the OFF timer is at fault. - Unit/system does not work
The indoor unit does not run at all. Check the power supply first, then check for diagnostic lights and voltage. - White mist from both indoor and outdoor units
Normal after the unit restarts in HEAT mode following a defrost cycle. - White mist from indoor unit
Normal in humid regions where a large temperature difference exists between room air and conditioned air. - Wire the signal and power cable to the indoor unit
The field 14/3 cable feeds power and communication from the outdoor unit to the indoor unit. - Wired remote control installation
The connection point depends on the wired controller model and the indoor unit size. - Wireless remote control installation
Mount the bracket at a customer-selected spot within operating range, then fit the batteries and place the remote in the bracket. - Zero crossing detection error
The control checks the zero crossing signal interval. The correct interval is 6 to 13 ms. If the interval is wrong for 240 seconds continuously, the u
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.