Electronic control board access, size 36K
What is going on
Steps to open the control box and remove the electronic control board and key board on the terminal board.
Check in this order
- Loosen the 4 hooks, then open the electronic control box cover.
- Remove the 6 screws on the electronic control board, then turn the board over.
- Pull out the connector.
- Remove the 4 screws, then remove the electronic control board.
- Pull out the connector, remove one screw, then remove the key board subassembly on the terminal board.
Applies to: DLCLRC outdoor unit, size 36K (Models 36AAK)
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLCLRC service manual, p. 45-46. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.