Bundle and wrap piping, drain hose and signal cable

DLFSHC

What is going on

Bundle the lines so the drain stays low and the line ends stay open for leak testing.

Check in this order

  1. Bundle the drain hose, refrigerant pipes and signal cable together.
  2. Keep the drain hose at the bottom of the bundle. At the top it can overflow the drain pan.
  3. Do not cross or twist the signal cable with other wiring.
  4. Attach the drain hose to the underside of the refrigerant pipes with adhesive vinyl tape.
  5. Wrap the bundle tightly with insulation tape, leaving the pipe ends unwrapped for leak checks.
  6. Seal the pipe ends before passing them through the wall to keep out dirt.

Applies to: DLFSHC indoor units

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSHC installation instructions, p. 13-14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.