Clean the air filters (monthly)
What is going on
Clogged filters cut cooling efficiency and can damage the indoor unit. Dusty sites need more frequent cleaning.
Likely causes
- Dust buildup on filters
- Torn or worn filters
Check in this order
- Turn off power at the outdoor disconnect and the indoor disconnect if separate.
- Unscrew the filters from the frame and pull them down to remove.
- Vacuum the filters.
- Wash with warm water.
- Shake out excess water and dry thoroughly.
- Slide the filter back into the rack until it snaps in.
- Close the front panel.
- Replace torn or badly worn filters. Get replacements from the dealer.
Applies to: Indoor unit air filters
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal IND-D DLFSDAH/DLFLDAH owner's manual, p. 11. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.