Daikin · Mini-split troubleshooting
INTELLIGENT EYE energy saving behaviour (FTXM09 / FTXM12 2-area)
What is going on
Explains why the unit may change setpoint or the INTELLIGENT EYE lamp may go off.
Likely causes
- No human movement detected in the room for 20 minutes.
- People sitting still or wearing clothes that the sensor does not pick up.
- Sensor mistakes pets, sunlight, moving curtains or mirror reflections for people.
- Sensor cannot detect movement beyond 23 ft (7 m).
- NIGHT SET mode does not start while INTELLIGENT EYE is in use.
Check in this order
- Confirm the INTELLIGENT EYE lamp is off to see energy saving has started.
- Move in the room, or wait; when movement is detected again the lamp lights and energy saving stops.
- If people sit near the front of the indoor unit, use COMFORT AIRFLOW together with INTELLIGENT EYE to keep air off them.
- Keep the sensor view clear of large objects and heat sources.
Applies to: FTXM09WVJU9, FTXM12WVJU9
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin Room Air Conditioner Operation Manual, p. 19-21. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.