Viessmann · Mini-split troubleshooting
Indoor unit shows two dashes (--) in a multi-zone system
What is going on
In AUTO on a multi-zone system the indoor unit can drop into STANDBY and show two dashes. This is expected behaviour, not a fault.
Likely causes
- AUTO changeover used on a multi-zone system
- Indoor unit waiting for all units to match the same mode (COOLING or HEATING)
Check in this order
- Set all indoor units in the system to the same mode, either COOLING or HEATING.
- Remember that HEATING is the system priority mode.
- Do not expect simultaneous HEATING and COOLING; it is not allowed.
- Use AUTO only on single zone applications.
Applies to: Multi-zone systems in AUTO mode
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann Vitocal IND-F DLFSFBH owner's manual, p. 3. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.