Electrical isolation before service
What is going on
Basic lockout requirement before installing, modifying or servicing the system.
Check in this order
- Set the main electrical disconnect to OFF before any install or service work.
- Check for more than one disconnect switch and turn off all of them.
- Lock out and tag each switch with a suitable warning label.
- Use only the specified wire and connect cables tight with clamps.
- Confirm the control board cover closes properly after wiring.
- Use a leakage-current device (RCD) rated 30 mA or less where the fixed-wiring rule applies.
Applies to: Indoor and outdoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Carrier D5FSOAH installation manual, p. 2-3. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.