Carrier · Mini-split troubleshooting
24K/36K/48K: evaporator and refrigerant sensor removal
What is going on
Removes the pipe clamp board, refrigerant sensor, evaporator fixing board and then the evaporator with its hangers.
Check in this order
- Remove the 2 screws of the pipe clamp board.
- Remove the 2 screws and take out the refrigerant sensor.
- Remove the 2 screws of the evaporator fixing board and remove it.
- Remove the 2 screws of the evaporator fixing hangers and remove the evaporator.
Applies to: 24K/36K/48K size indoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FSCAH / D5FLCAH service manual, p. 76. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.