Target discharge pipe temperature control
What is going on
The target discharge pipe temperature comes from the indoor and outdoor heat exchanger temperatures. The expansion valve opening is adjusted every 20 seconds so the actual discharge pipe temperature comes close to the target, giving indirect superheat control.
Check in this order
- If superheat looks wrong, check the discharge pipe temperature against the target over time.
Applies to: Outdoor unit EEV, feedback control
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin FTXM-W/V service manual, p. 87. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.